Product Description
The Lutron LUT-ELI-3PH Emergency Lighting Interface is a versatile and reliable solution designed to ensure seamless emergency lighting control in commercial and residential spaces. This advanced device integrates with Lutron lighting systems, activating emergency light levels during power outages or fire alarm events. Ideal for facilities requiring compliance with ULR 924 and other stringent safety standards, this unit is engineered for performance and ease of use.
Key Features
- Seamless Compatibility: Works with Lutron systems like GRAFIK Eye QS, Quantum hubs, Energi Savr Node units, and Vive wireless hubs.
- Automatic Emergency Activation: Senses line voltage loss (100–347 V) or receives signals from a Fire Alarm Control Panel (FACP).
- ULR 924 Certified: Meets industry standards for emergency lighting and power equipment.
- Test Button Functionality: Perform functional tests with a built-in test button.
- Energy-Efficient: Operates on a 24V power feed from a normal or emergency supply.
- Flexible Mounting: Fits standard 4x4 in. junction boxes.
Applications
The LUT-ELI-3PH is perfect for:
- Ensuring compliance in office buildings, hospitals, and schools.
- Maintaining safety in retail spaces and residential complexes.
- Supporting emergency lighting solutions in data centers and industrial facilities.
Specifications
- Input Voltage Range: 100–347 V
- Operating Temperature: 32°F to 104°F (0°C to 40°C)
- Certification: ULR 924, CSA C22.2 No. 141-02
- Mounting: 4x4 in. junction box
- Inputs: 2 FACP inputs (N/O or N/C dry contacts)
Installation
Installation Requirements: Connect to a 24V power source on a normal/emergency circuit. Short-circuit and overcurrent protection required.
FACP Integration: Accepts dry contact inputs from a fire alarm control panel.
Wiring Configurations:
- Compatible with single-phase, split-phase, and 3-phase systems.
- Supports up to 32 Quantum bus supplies or circuit selectors.
Frequently Asked Questions
Q1: What systems are compatible with the LUT-ELI-3PH?
A: The LUT-ELI-3PH is compatible with Lutron systems, including GRAFIK Eye QS, Quantum hubs, Energi Savr Node units, and Vive wireless hubs.
Q2: How does the LUT-ELI-3PH detect emergencies?
A: The device senses line voltage loss or receives a maintained dry contact signal from an FACP to trigger emergency lighting levels.
Q3: Is this unit suitable for outdoor use?
A: No, the LUT-ELI-3PH is designed for indoor use only, with an operating temperature range of 32°F to 104°F.
Q4: Does the device require a neutral wire?
A: Yes, proper short-circuit and overcurrent protection must be provided at the distribution panel.
Q5: How can I test the functionality of this device?
A: Use the built-in test button to simulate an emergency situation and verify system operation.