Product Description
Lutron RMJS-16R-DV-B PowPak Relay Module with Softswitch provides reliable, RF-based on/off control for general-purpose loads in Vive wireless lighting systems. Leveraging Lutron’s patented Softswitch technology, it pairs seamlessly with Pico remotes and Radio Powr Savr occupancy/daylight sensors to deliver long-life switching and flexible control without running new control wires.
RMJS-16R-DV-B PowPak Relay Module with Softswitch
- Load Rating: 16A general-purpose; motor: 1/2 HP @ 120V, 1-1/2 HP @ 277V
- Voltage: 120/277V~ (50/60Hz)
- RF Tech: Clear Connect (433.05–434.79 MHz)
- Wireless Inputs: Up to 10 Pico remotes, 10 occupancy/vacancy sensors, 1 daylight sensor
- Mounting: Exterior of U.S.-style junction box via standard knockout
Shipping: Free shipping on orders over $250
Benefits
- Long-life switching: Softswitch design prevents relay arcing to extend product life and reduce maintenance.
- Wire-free control: Add Pico remotes and Radio Powr Savr sensors for flexible, scalable control without pulling new control wires.
- Fast commissioning: Works stand-alone or with a Vive hub for simple browser-based setup, monitoring, and control.
- Versatile loads: Handles incandescent, MLV/ELV, resistive, inductive, magnetic/electronic fluorescent, and small motors.
Key Features
- Patented Softswitch eliminates contact arcing for an average of 1 million cycles.
- Clear Connect RF for reliable communication; typical 30 ft (9 m) through walls, up to 60 ft (18 m) line of sight to inputs.
- Power failure memory restores last state after interruptions.
- LED status indicator for load state and programming feedback.
- Plenum rated for environmental air spaces per NEC 300.22(C)(3).
- Optional CCO model (RMJS-16RCCO1DV-B) provides occupancy status to 3rd-party systems.
Specifications
Technical Specs
Model | RMJS-16R-DV-B |
Operating Voltage | 120/277 V~ (50/60 Hz) |
Standby Power | < 1.0 W |
RF Technology / Band | Clear Connect RF / 433.05–434.79 MHz |
Wireless Inputs | Up to 10 Pico remotes, 10 occupancy/vacancy sensors, 1 daylight sensor |
Ambient Operating Temp | 32°F to 131°F (0°C to 55°C), 0–90% RH non-condensing |
Performance Specs
Load Types | Incandescent, MLV, ELV, resistive, inductive, magnetic fluorescent, electronic fluorescent |
Load Rating | 16 A general-purpose (no minimum load) |
Motor Rating | 1/2 HP @ 120V~, 1-1/2 HP @ 277V~ |
Power Failure Memory | Restores previous state after power is restored |
Physical Specs
Mounting | Exterior of U.S.-style junction box via standard knockout |
Approx. Dimensions | 3.94" H × 3.42" W × 1.25" D (100 × 87 × 32 mm) |
LED Indicator | Status and programming feedback |
Compliance & Safety
Listings | UL Listed (U.S.), FCC Part 15 Class B |
Plenum Use | Meets NEC 300.22(C)(3); classified per CAN/ULC-S142 for air-handling spaces |
Warranty | 1 year limited (extendable to 5 years upon registration) |
Application Examples
- Classrooms, offices, and conference rooms needing sensor-based on/off control
- Retail sales floors with wireless scene control via Pico remotes
- Corridors and restrooms with occupancy/vacancy sensing
- Retrofits where adding control wiring is costly or impractical
Installation Tips
- Mount the module on the exterior of a junction or marshalling box; do not enclose in metal housings.
- Center the module in the room to maximize RF coverage; avoid foil-backed/metallic ceiling tiles when possible.
- Keep wireless inputs within 30 ft (9 m) through walls or 60 ft (18 m) line of sight of the module.
- Follow local and national electrical codes; verify load type and ampacity before wiring.
- Use the Vive hub (optional) for browser-based setup, monitoring, and future reprogramming.
FAQ
Q: What loads can the RMJS-16R-DV-B switch?
A: It supports general-purpose loads up to 16A including incandescent, MLV/ELV, resistive, inductive, and magnetic/electronic fluorescent loads, plus small motors within the listed HP ratings.
Q: Do I need a Vive hub to use this module?
A: No. It works stand-alone with Pico remotes and Radio Powr Savr sensors. A Vive hub is optional for centralized setup, control, and monitoring.
Q: How many wireless devices can I pair?
A: Up to 10 Pico remotes, up to 10 occupancy/vacancy sensors, and 1 daylight sensor per module.
Q: What is the RF range?
A: Inputs should be within about 30 ft (9 m) through walls or up to 60 ft (18 m) line of sight from the module.
Q: Is there an option for building management system integration?
A: Yes. Choose the CCO variant (RMJS-16RCCO1DV-B) for a maintained dry-contact output to signal occupancy status to third-party systems.
Q: Does it support emergency lighting?
A: Emergency operation is available on the -EM model (RMJS-16R-DV-B-EM). The standard RMJS-16R-DV-B is not an emergency unit.
Q: Can it be installed in plenum spaces?
A: Yes. It complies with NEC 300.22(C)(3) for use in other spaces used for environmental air, and is classified per CAN/ULC-S142.
Q: What happens after a power outage?
A: The module features power-failure memory and returns to the previous state when power is restored.