ONW-P-1001-DMV-W Greengate NeoSwitch PIR Dual Relay is a wall switch sensor from Cooper Lighting Solutions’ Greengate line that combines passive infrared detection with two independent relays for controlling separate loads, delivering energy savings, code-friendly operation, and a clean designer look in one device. Standard models cover 120/277V with 180°/1000 sq. ft. coverage, and a 347V variant (ONW-P-1001-D347) is available for Canadian and commercial applications.
Quick Specs
- Technology: Passive Infrared (PIR), self-adjusting time delay
- Relays: Dual, independently configurable Auto/Manual ON
- Voltage: 120/277VAC (DMV); 347VAC option (D347)
- Coverage: 180° up to 1000 sq. ft.; major motion 36’×30’, minor 20’×16’
- Loads (120V): Incandescent 0–800W; Fluorescent 0–1200W; LED/Electronic Ballast 3A
- Loads (277V): Fluorescent 0–2700W; LED/Electronic Ballast 3A
- Loads (347V D347): Fluorescent 0–1500W; LED/Electronic Ballast 3A
- Certifications: cULus, FCC, RoHS; California Title 20 Compliant
Perk: Free shipping on orders over $250
Benefits
- Two loads, one control: Manage lights/fans or two lighting zones from a single wall location to simplify wiring and reduce device count.
- Set-and-forget energy savings: Self-adjusting PIR and selectable time delays prevent nuisance shutoff while maximizing savings.
- Daylight hold-off: Built-in light level sensor keeps lights off when natural light is sufficient.
- Code-ready & reliable: Air-gap switch, verified coverage to NEMA WD7 methods, and Title 20 compliance support commercial specs.
Key Features
- PIR detection with 180° coverage and 1000 sq. ft. range.
- Dual relays with independent Auto/Manual ON selection.
- Self-adjusting time delays (test 15 sec; user 5/15/30 min).
- EcoMeter LED provides visual energy-use feedback and night-light locator.
- Daylighting selectable per relay (0–200 fc setpoint).
- Bathroom mode extends fan relay after lights turn off; Relay Swap corrects miswired loads without rework.
- Air-gap switch ensures no leakage current to load.
Enhanced Specifications
Technical Specs
| Technology | PIR (line-of-sight) |
| Coverage | 180°; up to 1000 sq. ft.; Major 36’×30’, Minor 20’×16’ |
| Time Delay | Self-adjusting; selectable 5 / 15 / 30 min (15 sec test) |
| Daylight Setpoint | 0–200 foot-candles (per relay) |
| Compliance | cULus, FCC, RoHS; California Title 20 |
Electrical / Performance
| Parameter | 120V (DMV) | 277V (DMV) | 347V (D347) |
|---|---|---|---|
| Incandescent | 0–800W | — | 0–1500W |
| Fluorescent | 0–1200W | 0–2700W | 0–1500W |
| LED/Electronic Ballast | 3A | 3A | 3A |
| Motor | ¼ HP @ 125VAC | — | — |
| Voltage / Frequency | 50/60 Hz | ||
Physical
| Mounting Plate | 4.195" H × 1.732" W |
| Housing Size | 2.618" H × 1.752" W × 1.9" D |
| Environment | 32°F–104°F (0–40°C), 20–90% RH, Indoors only |
| Housing Material | Durable injection-molded; UL 94V-0 |
Application Examples
- Private offices and small conference rooms
- Break rooms, lounges, and waiting areas
- Small classrooms and restrooms (no stalls)
- Closets and storage rooms
Installation Tips
- Ground required: Device must be grounded for proper operation.
- Mounting: Fits standard 3.5" deep single-gang box; include supplied wallplate (347V model excludes wallplate).
- Wiring options: Single-circuit dual-level, dual-circuit, and three-way configurations—see diagrams.
- Commissioning: After power-up, allow ~2 minutes to stabilize; use test mode for aiming and set 5/15/30 min delays.
- Daylighting: Set threshold with ambient light present; enable per relay via DIP 11/12.
- Cleaning: Avoid ammonia/VOC cleaners; use mild detergent or approved wipes only.
FAQ
Does this model control two separate loads?
Yes. It has two independent relays that you can configure for Auto or Manual ON per relay.
What voltages are supported?
The DMV models support 120/277VAC; the D347 model supports 347VAC. Both operate at 50/60 Hz.
How large is the coverage area?
Up to 1000 sq. ft. (180°). Typical major motion coverage is 36’×30’ and minor motion is 20’×16’.
Can it keep lights off when there’s enough daylight?
Yes. A built-in light level sensor (0–200 fc) can hold one or both relays off when ambient daylight is sufficient.
What are the time delay options?
Self-adjusting with a 15-second test mode and selectable 5, 15, or 30 minute settings.
Is there a bathroom/fan option?
Yes. Bathroom mode keeps the second relay on for an additional 8 minutes after the first relay switches off.
What are the load ratings for LED fixtures?
Electronic ballast/LED loads are rated 3A across 120V, 277V, and 347V models.
Is the device Title 20 compliant?
Yes—California Title 20 compliant, and listed to cULus, FCC, and RoHS.
What does the EcoMeter do?
The green LED provides visual feedback of energy usage and acts as a locator/night light.
Are cleaning chemicals a concern?
Avoid ammonia-based or harsh cleaners; they can damage the device. Use mild detergent or approved wipes.