Product Description
PRODUCT SHIPS OUT IN 4-6 WEEKS
Lutron EC5T832GUNV3L EcoSystem Five-Input Digital Dimming Ballast delivers continuous 100%–10% fluorescent dimming for two F32T8 lamps with both EcoSystem digital link control and 3-wire phase control, ideal for energy savings, occupant comfort, and flexible control in commercial lighting upgrades.
Model: EC5T832GUNV3L
Lamp Compatibility: Two F32T8 (T8 linear)
Dimming Range: 100%–10% (continuous, flicker-free)
Control Inputs: EcoSystem digital link, 3-wire phase, Daylight, Occupancy, IR/Wallstation
Voltage: Universal 120/220-240/277 V, 50/60 Hz
Ballast Factor: 0.85 (default)
Case Type: G (with leads)
Power Factor / THD: ≥0.95 PF / <10% THD
Sound Rating: Class A
Perk: Free shipping on orders over $250
Product Benefits
- Energy savings without sacrifice—smooth dimming down to 10% lowers wattage while maintaining comfortable, consistent light output.
- Flexible control options—works on the EcoSystem digital link for networked control, or via 3-wire wallbox dimmers for local control.
- Integrated sensor support—connect occupancy and daylight sensors directly to the ballast for code-friendly, space-level control.
- Quiet, reliable operation—programmed rapid-start design, end-of-lamp-life protection, and ultra-quiet Class A sound rating.
Key Features
- Five control inputs: EcoSystem link, 3-wire, daylight sensor, occupancy sensor, and personal control (IR/wallstation).
- Non-volatile memory restores settings after power loss; factory 100% tested for performance.
- Low harmonics across the dimming range with THD <10% and power factor ≥0.95.
- Protected against miswires on inputs and lamp leads for safer installation.
- BAA-compliant models available (order with “U” prefix, when applicable).
Specifications
Technical Specs
| Model | EC5T832GUNV3L |
| Lamp Type / Qty | T8 linear, 2 lamps (F32T8) |
| Control | EcoSystem digital link (E1/E2), 3-wire phase, Daylight, Occupancy, IR/Wallstation |
| Dimming Range | 100% to 10% (continuous, flicker-free) |
| Start Method | Programmed rapid start |
| Case Type | G (with factory leads) |
Electrical / Performance
| Voltage / Frequency | Universal 120/220-240/277 V, 50/60 Hz |
| Ballast Factor | 0.85 (default for T8) |
| THD | <10% |
| Power Factor | ≥0.95 |
| Inrush Current (typ.) | 3 A @ 277 V; 7 A @ 120 V |
| Class 2 Aux Output | +20 V-, 50 mA max for sensors/wallstation |
Physical
| G-Case Dimensions | A: 9.5 in, B: 8.9 in, C: 7.1 in, D: 1.0 in, E: 2.38 in |
| Lead Lengths | Lamp: 36 in; Line/Neutral/E1/E2: 18 in |
| Sound Rating | Class A |
| Max Case Temp | 167 °F (75 °C) |
Compliance & Safety
| Listings | UL Listed, CSA Certified, S-Mark; Class P thermally protected |
| Standards | Meets ANSI C82.11; FCC Part 18 (Non-Consumer) |
| Surge Protection | ANSI C62.41 Category A up to 4 kV |
| Environment | Min. lamp start temp 50 °F (10 °C); RH <90% non-condensing |
Application Examples
- Open offices & classrooms—pair with occupancy and daylight sensors for automatic savings.
- Conference rooms—EcoSystem scenes via wallstations or IR for presentations.
- Corridors & break areas—3-wire local dimming with future-ready digital link.
- Retrofits—drop-in T8 ballast replacement where networked control is planned.
Installation Tips
- Do not switch the line/hot feeding the ballast if using EcoSystem link—keep line unswitched for full system functionality.
- Lead lengths: keep ballast-to-lamp socket wiring ≤7 ft for T8; Class 2 sensor runs up to 50 ft using 22 AWG solid.
- Separate Class 1 and Class 2 wiring; where not possible, use 600 V insulated cable with shield bonded to ground.
- Mounting clearance: maintain proper lamp-to-grounded metal spacing to avoid flicker and extend lamp life.
- Verify polarity-insensitive E1/E2 wiring; use consistent wire colors across fixtures to reduce errors.
FAQ
Does this ballast require the EcoSystem digital link to operate?
No. It can operate stand-alone with 3-wire phase control or as part of a network on the EcoSystem digital link.
What lamps are supported?
Two F32T8 linear fluorescent lamps. Other EC5 models support different lamp types; this model is optimized for T8.
How low can it dim?
Continuous dimming down to 10% relative light output.
Can I connect sensors directly?
Yes. One occupancy sensor, one daylight sensor, and one IR/wallstation input are supported via Class 2 terminals.
Is the EcoSystem link polarity sensitive?
No. E1 and E2 are polarity-insensitive and support various topologies.
What’s the maximum wiring distance on the EcoSystem link?
Depends on wire gauge; for example, 18 AWG supports up to 550 ft and 12 AWG up to 2200 ft on a single link.
Is it suitable for emergency lighting?
Not when controlled by a 3-wire wallbox dimmer unless an external emergency ballast is used or the circuit is from a dedicated emergency dimming panel.
Will settings be lost after a power outage?
No. The ballast uses non-volatile memory to restore previous settings.
What is the maximum case temperature?
167 °F (75 °C). Do not exceed this at any point on the case.
Is there audible noise during dimming?
No. The ballast is rated Class A for ultra-quiet operation.