Product Description
The FV-04VE1 WhisperComfort® Spot Energy Recovery Ventilator (ERV) by Panasonic provides balanced ventilation for single rooms or small spaces. Utilizing two 4-inch ducts, it exhausts stale indoor air and supplies fresh outdoor air, maintaining indoor air quality and balanced air pressure.
Key Features:
- Balanced Ventilation: Simultaneously exhausts indoor air and supplies fresh outdoor air to maintain indoor air quality.
- Energy Recovery: Transfers heat and moisture between incoming and outgoing air streams to enhance energy efficiency.
- Compact Design: Ceiling-insert design fits between 16-inch on-center joists for easy installation.
- Quiet Operation: Operates at noise levels as low as <0.3 sones for whisper-quiet performance.
- Frost Prevention Mode: Built-in technology prevents core freeze-up in colder temperatures.
- Compliance: Meets ASHRAE 62.2, LEED, California Title 24, and Washington State Ventilation and Indoor Air Quality Code standards.
Specifications:
- Airflow Settings: 40/20 CFM or 20/10 CFM
- Exhaust Air Volume: 40, 20, or 10 CFM
- Supply Air Volume: 30, 20, or 10 CFM
- Noise Level: 0.8 sones at 40 CFM; <0.3 sones at 20 CFM
- Power Consumption: 23W at 40 CFM; 21W at 20 CFM; 17W at 10 CFM
- Dimensions: Housing: 14 inches wide; Grille: 20-3/4 inches x 16-3/4 inches
- Duct Compatibility: Two 4-inch ducts
- Apparent Sensible Effectiveness for Heating: 66% at 30 CFM and 32°F (0°C)
- Total Recovery Efficiency for Cooling: 36% at 29 CFM and 95°F (35°C)
- Warranty: 3 years on all parts
Installation Tips:
- Ensure the unit is installed between joists spaced 16 inches on-center.
- Utilize the adjustable mounting brackets and screws provided for secure installation.
- Follow the detailed instructions in the installation guide for proper setup and wiring.
- Regularly clean the supply and exhaust air filters to maintain optimal performance.
Frequently Asked Questions:
Q: Can this ERV be installed in a bathroom?
A: No, the FV-04VE1 is not designed for bathroom installations. It is ideal for single rooms like home offices, game rooms, or family rooms.
Q: How does the frost prevention mode work?
A: The built-in frost prevention technology automatically adjusts the operation to prevent the core from freezing in low temperatures.
Q: What maintenance is required for this ERV?
A: Regularly clean the two air filters—one located on the inside louver of the grille and the other within the unit—to ensure efficient operation.
Q: Does this unit comply with energy efficiency standards?
A: Yes, it meets ASHRAE 62.2, LEED, California Title 24, and Washington State Ventilation and Indoor Air Quality Code standards.
Q: What are the power requirements for this ERV?
A: The unit operates on 120V/60Hz power, with power consumption varying by airflow setting.